Direct Flow High Pressure Industrial Steam Boiler
Product Details
| Customization: | Available |
|---|---|
| Function: | Water Boiler, Steam Boilers, Hot Water Boiler, Hot Air Boiler |
| Fuel: | Natural Gas/Diesel |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Manufacturer/Factory & Trading Company
360° Virtual Tour
Secured Trading Service
Diamond Member Since 2025
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Quality Assurance
Management Certification
The supplier has import and export rights
The supplier provides quality assurance
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Sign In to see all verified strength labels (20)
Find Similar Products
Basic Info.
- Model NO.
- PZ series
- Installation
- Bulk Boiler
- Structure
- Fire Tube
- Media
- Steam
- Water Circulation
- Natural Circulation
- Drum Placement
- Vertical Boiler
- Pressure
- High Pressure
- Manufacturing Level
- A
- Burning Style
- Chamber Combustion Boiler
- Usage
- Industrial, Vehicle, Power Station
- Delivery Time
- 30 Days
- MOQ
- 1
- Free Samples
- No
- Steam Temperature
- up to 650°C
- Capacity Range
- Modular System up to <200 Tons of Steam
- Transport Package
- Wooden Packaging
- Specification
- Customized
- Trademark
- Weifu
- Origin
- Jiangsu
Packaging & Delivery
- Package Size
- 700.00cm * 800.00cm * 1350.00cm
- Package Gross Weight
- 220.000kg
Product Description
Product features and advantages
Stable and mature
Adopting the advanced DC coil design technology of Heidelberg (Thermal Energy)Technology Company in Germany,this type of DC coil steam boiler is stable,energy-saving,and mature.It has been used in Europe for more than 60 years.
Blowdown without boiler shutdown
With a unique direct-current coil design, the steam boiler requires no blowdown or shutdown during operation, making it more convenient and energy-efficient.
Absolutely safe with no hidden risks
Thanks to its small water capacity spiral coil design and the absence of a steam drum, the direct-current coil steam boiler is inherently explosion-proof. Since its introduction, there has never been a single explosion-related accident or casualty associated with this type of boiler.
Stable and mature
Adopting the advanced DC coil design technology of Heidelberg (Thermal Energy)Technology Company in Germany,this type of DC coil steam boiler is stable,energy-saving,and mature.It has been used in Europe for more than 60 years.
Blowdown without boiler shutdown
With a unique direct-current coil design, the steam boiler requires no blowdown or shutdown during operation, making it more convenient and energy-efficient.
Absolutely safe with no hidden risks
Thanks to its small water capacity spiral coil design and the absence of a steam drum, the direct-current coil steam boiler is inherently explosion-proof. Since its introduction, there has never been a single explosion-related accident or casualty associated with this type of boiler.
Two placement forms
It can be flexibly placed vertically or horizontally according to the actual situation on site
Steam pressure
1.25 MPa-23.0MPa,with an overheating temperature of up to 650ºC Customizable according to requirements.
energy-saving
Thanks to its unique structural design, the direct-current coil steam boiler requires no preheating and can generate steam within 3-5 minutes after startup. It delivers steam on demand, ensuring immediate use with zero waste.
Advanced Services
The HD direct-current coil steam boiler adopts IoT (Internet of Things) technology and connects to the manufacturer's computer service center for 24/7 real-time monitoring. This enables proactive fault detection and prevention, ensuring safe and reliable operation throughout the year.
It can be flexibly placed vertically or horizontally according to the actual situation on site
Steam pressure
1.25 MPa-23.0MPa,with an overheating temperature of up to 650ºC Customizable according to requirements.
energy-saving
Thanks to its unique structural design, the direct-current coil steam boiler requires no preheating and can generate steam within 3-5 minutes after startup. It delivers steam on demand, ensuring immediate use with zero waste.
Advanced Services
The HD direct-current coil steam boiler adopts IoT (Internet of Things) technology and connects to the manufacturer's computer service center for 24/7 real-time monitoring. This enables proactive fault detection and prevention, ensuring safe and reliable operation throughout the year.
Reliability & Energy Efficiency
The boiler is equipped with a plunger pump or diaphragm pump, using fully proportional variable frequency control to deliver continuous feedwater. This maximizes continuity and energy efficiency, while avoiding frequent pump start-stop cycles. As a result, the quality of high-dryness steam is consistently ensured.
Modular boiler design for higher system efficiency
Direct-current coil steam boilers support a modular configuration (up to <200 tons of steam), allowing multiple units to operate in parallel. Thanks to their unique rapid start-up response, the number of operating units can be closely matched to real-time steam demand. This ensures that each boiler operates at peak efficiency, effectively avoiding the energy waste often seen with oversized single boilers running under low load. As a result, the overall thermal efficiency of the boiler system is significantly improved.
The boiler is equipped with a plunger pump or diaphragm pump, using fully proportional variable frequency control to deliver continuous feedwater. This maximizes continuity and energy efficiency, while avoiding frequent pump start-stop cycles. As a result, the quality of high-dryness steam is consistently ensured.
Modular boiler design for higher system efficiency
Direct-current coil steam boilers support a modular configuration (up to <200 tons of steam), allowing multiple units to operate in parallel. Thanks to their unique rapid start-up response, the number of operating units can be closely matched to real-time steam demand. This ensures that each boiler operates at peak efficiency, effectively avoiding the energy waste often seen with oversized single boilers running under low load. As a result, the overall thermal efficiency of the boiler system is significantly improved.
| PZ/L(W) Technical Specifications Table | |||||||||||
| Technical Specifications | Unit | PZ500 | PZ1000 | PZ1500 | PZ2000 | PZ3000 | PZ4000 | PZ5000 | |||
| Rated Steam Output | kg/h | 500 | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | |||
| Design Pressure | Mpa | 1.25~23.0 | 1.25~23.0 | 1.25~23.0 | 1.25~23.0 | 1.25~23.0 1.25~23.0 1.25~23.0 | |||||
| Design Thermal Efficiency (with Energy Saver) | % | ≥95.5 | |||||||||
| Design Thermal Efficiency (with Condenser) | % | ≥102 | |||||||||
| Operating Water Vessel | L | 47 | 72 | 159 | 240 | 385 | 458 | 615 | |||
| Natural Gas Connection | DN | 25 | 40 | 50 | 50 | 50 | 65 | 65 | |||
| Feedwater Inlet Diameter | DN | 20 | 20 | 25 | 25 | 32 | 40 | 40 | |||
| Drainage Outlet Diameter | DN | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |||
| Flue Gas Outlet Diameter | mm | φ211 | φ273 | φ312 | φ355 | 270×700 | 316×1100 | 316×1200 | |||
| Steam Outlet | DN | 50 | 65 | 65 | 65 | 80 | 100 | 100 | |||
| Safety Valve Diameter | DN | 25/32 | 32/40 | 40/50 | 50/65 | 65/80 | 2-50/65 | 2-50/65 | |||
| Vertical Placement | Length | mm | 1524 | 1680 | 2172 | 2152 | 2498 | 3037 | 3037 | ||
| Width | mm | 1326 | 1627 | 1967 | 1967 | 2172 | 2148 | 2148 | |||
| Height | mm | 1774 | 2163 | 2570 | 3073 | 3272 | 4365 | 5200 | |||
| Horizontal Placement | length | mm | 1774 | 2163 | 2570 | 3073 | 3272 | 4365 | 5200 | ||
| width | mm | / | 1627 | 1967 | 1967 | 2172 | 2226 | 2226 | |||
| height | mm | / | 1781 | 2264 | 2264 | 2440 | 3149 | 3250 | |||
| Total Power Consumption | KW | 3.8 | 5.8 | 7 | 9.3 | 13.5 | 18.5 | 21.2 | |||
| Fuel Consumption @ 100% Load | |||||||||||
| High-Efficiency Condensing Type (20°C Feedwater) | Nm³/h | 36.4 | 72.7 | 109.1 | 145.1 | 217.2 | 287.2 | 359 | |||
| High-Efficiency Standard Type (20°C Feedwater) | Nm³/h | 38.9 | 77.5 | 116.3 | 154.6 | 230.8 | 309.3 | 386.6 | |||
| Standard Power Supply | 220V/380V × 3-Phase with Neutral / 50Hz | ||||||||||
| Feedwater and Boiler Water Standards | EN12952-12:2003 (EU Standard) | ||||||||||
| Net Weight of the Boile | t 1.5 2.0 3.1 3.2 4.8 8.4 9.1 | ||||||||||
| PZ/L(W) Technical Specifications Table | ||||||||||
| Technical Specifications | Unit PZ6000 | PZ8000 | PZ10000 PZ12000 | PZ15000 PZ20000 | ||||||
| Rated Steam Generation Capacity | kg/h | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 | |||
| Design Pressure | Mpa | 1.25~23.0 | 1.25~23.0 | 1.25~23.0 1.25~23.0 | 1.25~23.0 | 1.25~23.0 | ||||
| Design Thermal Efficiency (with Energy Saver) | % | ≥95.5 | ||||||||
| Design Thermal Efficiency (with Condenser) | % | ≥102 | ||||||||
| Operating Water Vessel | L | 735 | 858 | 977 | 1290 | 1685 | 1980 | |||
| Natural Gas Connection | DN | 80 | 100 | 100 | 125 | 125 | 125 | |||
| Feedwater Inlet Diameter | DN | 50 | 50 | 50 | 65 | 65 | 80 | |||
| Drainage Outlet Diameter | DN | 40 | 40 | 40 | 50 | 50 | 80 | |||
| Flue Gas Outlet Diameter | mm | 400x1050 | 400x1150 | 400x1200 | φ700 | 800 | 900 | |||
| Steam Outlet | DN | 125 | 150 | 150 | 150 | 200 | 200 | |||
| Safety Valve Diameter | DN | 2-65/80 | 2-80/100 | 2-80/100 | 2-80/100 | 2-100/125 | 2-100/125 | |||
| Vertical Placement | length | mm | 3922 | 4235 | 4557 | 4880 | 4930 | 5830 | ||
| width | mm | 2726 | 3210 | 3050 | 3880 | 4360 | 4580 | |||
| height | mm | 5300 | 5800 | 6200 | 6520 | 6830 | 8240 | |||
| Horizontal Placement | length | mm | 5300 | 5800 | 6200 | 6520 | 6830 | 8240 | ||
| width | mm | 3115 | 3210 | 3250 | 3880 | 4360 | 4580 | |||
| height | mm | 3226 | 3550 | 3580 | 4580 | 4630 | 5530 | |||
| Total Power Consumption | KW 22.0 | 23.5 | 35 | 38 | 50 | 68.5 | ||||
| Fuel Consumption @ 100% Load | ||||||||||
| High-Efficiency Condensing Type (20°C Feedwater) | Nm³/h | 430.8 | 574.4 | 718 | 861.1 | 1077 | 1436 | |||
| High-Efficiency Standard Type (20°C Feedwater) | Nm³/h | 463.9 | 618.6 | 773.2 | 927.84 | 1159.8 | 1546.4 | |||
| Standard Power Supply | 220V/380V × 3-Phase with Neutral / 50Hz | |||||||||
| Feedwater and Boiler Water Standards | EN12952-12:2003 (EU Standard) | |||||||||
| Net Weight | t 10.5 12.3 12.8 13.6 16.5 22.6 | |||||||||
Jiangsu Weifu Special Equipment Co.Ltd. is located at Tieta Road, Guyang Town, Dantu District, Zhenjiang City.The company is committed to integrating boiler marketing resources throughout mainland China, and through the marketing network, it conveys the concept, quality, price, and service of Weifu (oil, gas, electricity) boilers to customers. The company follows the concept of "being a real person and doing things honestly", making fine products and warming the world. The company advocates that in the process of Weifu boiler market operation, customers get value, employees get improvement, shareholders get benefits, companies get development, and the country gets tax revenue.
The company currently has more than 200 employees, including more than 40 professional technicians of various types. The company has more than 20, 000 square meters of modern factory buildings and advanced manufacturing and testing equipment, specializing in the design and manufacture of gas (oil, electricity) hot water boilers, gas (oil, electricity) steam boilers, gas (oil, electricity) vacuum hot water boilers, and gas (oil, electricity) organic carrier boilers.
The company follows the business philosophy of "what customers need is what we make", takes boiler products as the main product, and has developed vertical/horizontal gas (oil) steam boilers, vertical gas (oil) normal pressure/pressure hot water boilers, horizontal gas (oil) steam boilers, horizontal gas (oil) normal pressure/pressure hot water boilers, electric heating steam boilers, electric heating normal pressure hot water boilers, gas (oil) thermal oil boiler series products, a total of 7 series and nearly 300 specifications. The company′s products all adopt clean combustion technology. The horizontal pressure boiler body design adopts advanced structures such as corrugated furnace, conical furnace, threaded smoke pipe, wet back three-pass, etc. The boiler main engine is equipped with imported burners such as Riello, Aucma, Black & Decker, and Weishaupt, achieving the effect of high efficiency, energy saving and environmental protection of the boiler. The boiler is equipped with pressure or normal pressure economizers and condensers to further reduce the boiler exhaust temperature, while reducing the concentration of dust, nitrogen oxides and sulfur oxides in the flue gas, making the boiler more energy-saving and more environmentally friendly. Weifu Boiler has become a national supplier of small and medium-sized oil (gas, electric) boilers in China. Its customers are located in large and medium-sized cities in mainland China. It has contributed to environmental protection and energy conservation in mainland China.
The company Holds a national Class B manufacturing certificate,Facing the boiler market where opportunities and challenges coexist, Weifu Boiler adheres to the principle of "creativity for development, credit for cooperation, quality for market share". We will share the value of Weifu Boiler with you.
1. How to buy a good boiler?
A: Choose a good supplier.
B: Specification is clear, steam or hot water, capacity,fuel,pressure and so on
C:Price is not the only problem, quality and service also important.
2. What is your main product?
A:Steam boiler, hot water boiler and thermal oil boiler.Gas fired boiler, oil fired boiler, diesel fired boiler, coal fired boiler, biomass fired boiler,Industry boiler and so on.
3. Q: How long is your lead time?
A: Generally it is 30 days, depends on your needs and project scales.
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Main products
- Direct Flow High Pressure Industrial Steam Boiler
Related Categories
Hot Searches
More